Category: Electric Locomotive

Laxven Multi-Functional Graphical Display System for Locomotives


Introduction

Laxven has developed a rugged, multi-functional graphical display system designed to function as a human-machine interface (HMI) for locomotive operators. The system enables operators to view and investigate critical parameters, control the locomotive, record/retrieve data, and change user-settable parameters. It interfaces with the locomotive’s control system, allowing for real-time data display and fault event recording. The display is suitable for a wide range of locomotives, including Diesel, Electric, Metro, DEMU, and EMU locomotives, with configurations for 3-phase locomotives as per customer specifications.

This system is powered by the DC voltage available in the locomotive and supports voltage variations from 40V to 140V DC. It records event and fault data, which can be downloaded via a USB Pen Drive for analysis.

Salient Features

Feature Description
Display Type 10.4 inch TFT LCD with sunlight-readable high brightness (1200 cd/m²)
Viewing Angle 88° on both sides for better visibility
Fast Boot-Up Boot time less than 5 seconds
Operating System Crash-proof real-time OS, unaffected by power interruptions
Power Consumption Ultra-low consumption: <10W at maximum brightness, <6W at nominal brightness
Brightness Adjustment Auto/manual adjustment based on the environment
Rugged Keypad IP65-rated, durable, with white backlight
Environmental Durability Withstands shocks, vibrations, and extreme temperatures encountered in locomotives
Railway Compatibility Complies with IEC 60571, IEC 61373, and IEC 61000 standards
Power Supply Range 40V to 140V DC for compatibility with all Indian Railway locomotives
Protection Features Reverse polarity, Over-voltage, Over-current, Short circuit protection
Communication Interface Ethernet or MVB, ensuring flexibility for different systems
Data Recording & Downloading Event and fault data can be downloaded via USB Pen Drive
Temperature Sensors Includes a temperature sensor, brightness sensor, and health monitoring system


Variants

Variant Specification Communication Interface Application
LAX-DIALS-12 Developed as per RDSO specification MP.0.0400.10 (Rev-03) Ethernet Communicates with Siemens S7-300 Loco Computer
LAX-DDU-14 Developed for 3-phase locomotives as per CLW specification CLW/ES/3/0487 TCN/MVB Communicates with Locomotive VCU via TCN/MVB protocol

Technical specification

Parameter Details
Power Supply Voltage 40V to 140V DC from loco battery (18V during cranking)
Power Consumption < 10W @ maximum brightness, Typical: 6W
EMI/EMC and ESD Protection Compliant with IEC 60571 and IEC 61000
Other Protections Reverse polarity protection, Short circuit protection
Operating System Real-Time Crash-Proof Operating System
Single Board Computer Quad-core processor with 8GB RAM
Display Size 10.4” high brightness LCD display
Display Brightness 1200 cd/m²
Display Resolution 1024 x 768
Keypad 3 keypads with 28 keys, IP65-rated membrane tactile keypad, white backlit
Storage Solid-state memory
Indications 5mm Bi-color LED (Red & Yellow)
Monitoring Hardware Health Monitoring System, Brightness Sensor, Temperature Sensor
Data Communication Ports Ethernet, MVB, RS485, USB
Data Downloading Ports USB Pen Drive
Display Brightness Control Manual or Auto operation via brightness sensor (adjustable from 20% to 100%)
Temperature Range -25°C to +85°C
Temperature Cutoff 75°C (user settable)
Weight of Equipment < 4 Kg
Enclosure IP Class Front side: IP65, Rear side: IP52

 